G Injector tower syring sensor assembly, used with series automatic liquid samplers, model GA. Automatic Liquid Sampler. USD. SubCat2ECS_ Sample Introduction and Syringes. $ Syringe motor assembly, used with series automatic liquid sampler systems, models A, B, and GA. Agilent Manuals. Agilent A Operation Manual. Agilent A GC Brochure. Getting Familiar With Your Agilent GC. Quick Reference Agilent GC. HP service manual. HP operating T GA Cool on-Column Conversion Kits. HP - BC Tray base-turret and flex. HP - B-C Tray turret. Troubleshooting Autosampler Errors However, Agilent Technologies, Inc. cannot assume responsibility for t he use of this material. The information contained herein is intended for use by informed individuals who can and must determine its fitness for their purpose.


Agilent Automatic Liquid Sampler. Part Number Introduction. The radial flex (R-flex) circuit (previously part no. ) has been redesigned and is now available as part no. This new circuit requires a modified turret (still part no. ). "B" trays. ment and written consent from Agilent Technologies, Inc. as governed by United States and international copyright laws. Manual Part Number G Edition First edition, August Printed in USA Agilent Technologies, Inc. Centerville Road Wilmington, DE USA Safety Notices CAUTION A CAUTION notice denotes a haz-ard. Agilent Technologies, Inc. Centerville Road Wilmington, DE Agilent Technologies Warnings in this manual or on the instrument must be observed during all phases of operation, service, and repair of Note Do not mount the GA Injector on a mounting post for a Injector.


the Autosampler System to help determine the site of the problem, i.e. in the injector (tower), controller, or vial tray (if present). Common problems stem from using vials that are not designed to work with. Warnings in the manual or on the instrument must be observed during all phases of operation, service, and repair of this instrument. Failure to comply with these precautions violates safety standards of design and the intended use of the instrument. Agilent Technologies assumes no liability for the customer’s failure to comply with these. Note Do not mount the GA Injector on a mounting post for a Injector. Remove the old post and replace it with the new one. 1. Install the mounting post on the injection port cover in the front or rear location, as desired. 2. Open the injector door. Slide the packing material and syringe carriage down, then remove the packing. 3. Mount.

0コメント

  • 1000 / 1000